OPEN-PATH
GAS DETECTION SYSTEMS
The
SafEye range of "line-of-sight" Optical Gas
Detectors by Spectrex-Inc. features a new generation of
Open Path IR and UV detection systems. Open path
spectroscopy offers unprecedented reliability in real-time
monitoring of gaseous emissions over large areas,
rendering it the accepted technology for industrial and
environmental applications.
These
systems provide exceptional detection capability of
gas/vapor concentrations ranging from as low as Parts Per
Million (PPM) levels to Lower Explosive Limit (LEL) levels
in a wide range of hazardous conditions and ambient air
monitoring.
SafEye
System employs a unique flash light source coupled with
optical detectors and mathematical algorithms to spectrally
analyze an air path ranging from 2 ft. to 450 ft. (0.6m -
140m) with high detection sensitivity in both UV and IR
spectral bands. The system is compatible
with a wide range of control systems providing multiple
outputs (dry contacts, 4-20mA, RS-485).
The
open path line-of-sight gas detection system can monitor and
transmit an alarm signal prior to occurrence of fire or an
explosion, identify the chemical family concerned and
activate preventative systems.
The
SafEye gas detection system can serve as a process control
component in the chemical and petrochemical industries, or
as a safety system in commercial and industrial
applications.
SafEye
Range of Gas Detectors
Typical
Gas Detection Applications
The
major growth of use of Open Path systems is in the area of
oil and gas offshore production platforms, FPSOs and onshore
production. Spectrex is particularly active with its SafEye
Open Path Gas Detectors in offshore Britain (North Sea) and
offshore Norway (North Sea).
SafEye
systems can be very useful in additional applications such
as:
-
Combustion Monitoring - SafEye gas detector can be used to
monitor combustion efficiency in various chemical processes
by analyzing the ratio of combustion products such as Carbon
Monoxide (CO), Carbon Dioxide (CO2) and unburned
Hydrocarbons (HC).
-
Online Process Control - SafEye Open Path gas detector can
be used to monitor chemical processes by analyzing the
emitted gases and relative concentrations. The system can
monitor Ammonia, aromatic compounds like Benzene, Toluene
and Styrene, Hydrogen Sulfide (H2S, CS2),
Carbon Disulfide, Aliphatic Sulfides, Aliphatic Mercaptans,
and many other gaseous compounds.
-
Environmental Monitoring - SafEye line of sight detectors
can monitor toxic vapors or hazardous/flammable gases
originating from industrial processes for the purpose of
worker safety and the prevention of environmental
contamination.
Typical
Gas Detection Installations
-
Oil
and gas industry - offshore and onshore platforms,
refineries, storage facilities and pipelines
-
Petrochemical,
pharmaceutical, chemical process, storage and production
areas
-
Waste
treatment and disposal sites
-
Hazardous
materials loading docks, transportation and shipping
depots and warehouses
-
Compressors,
turbines and pumping stations
-
Paint
spray booths in automotive manufacturing
-
Fuel
and gas storage loading and distribution terminals, LNG
- LPG systems and natural gas bus garages
-
Process
control applications including:
-
Gas
monitoring in chemical processes
-
Desulfurization
process (H2S)
-
Monitoring
toxic and flammable gases in air-ducts and
air-intakes
|